Respond to all Summons buttons

  • When arriving at a floor stop then open the doors and keep them open for 5 seconds after the plane of the door is broken, with the timer resetting each time the plane is broken
  • If the summons was an Up summons respond to all destination buttons above the current floor first.
  • If the summons was a Down summons respond to all destination buttons below the current floor first
  • When completing a destination buttons order only respond to summons going the same direction.
  • If multiple destination buttons are pressed prioritize the direction used on the summons and then proximity stopping on the closest floor each time.
  • Prioritize destination buttons over summons buttons